Age | Commit message (Collapse) | Author |
|
lib1515.c:38:26 warning: unused parameter 'curl'
lib1515.c:38:81 warning: unused parameter 'ptr'
lib1515.c:38:5 warning: no previous prototype for 'debug_callback'
lib1515.c:46:5 warning: no previous prototype for 'do_one_request'
lib1515.c:120:3 warning: ISO C90 forbids mixed declarations and code
As well as some code policing such as white space and braces.
|
|
Not comma, which is an inconsistency and a mistake probably inherited
from the examples section of RFC1867.
This bug has been present since the day curl started to support
multipart formposts, back in the 90s.
Reported-by: Rob Davies
Bug: http://curl.haxx.se/bug/view.cgi?id=1333
|
|
|
|
Fix for bug #1303 (030a2b8cb) was not complete.
libcurl still pruned DNS entries added manually
after detecting a dead connection. This test
checks such behavior.
|
|
Test-case 1515 reproduces bug #1303, where libcurl
would incorrectly prune DNS entries added via
CURLOPT_RESOLVE after the DNS_CACHE_TIMEOUT had
expired.
|
|
Leave the valgrind --gen-suppressions option in there, commented, to
make it easier for next update.
|
|
The call stack was modified in 2dc7ad23 so the supressions didn't work
anymore.
|
|
... caused false detections of the threaded resolver otherwise
|
|
|
|
The test contains a cookie jar file where one of the cookies has an
expiry date of 1391252187 -- Sat, 1 Feb 2014 10:56:27 GMT which has
now expired. Updated to Wed, 14 Oct 2037 16:36:33 GMT as per test
179.
Reported-by: Adam Sampson
Bug: http://curl.haxx.se/bug/view.cgi?id=1330
|
|
Since the timer resolution is lower, there are actually cases that
the compared values are equal. Therefore we check for previous
timestamps being greater than the current one instead.
|
|
Since the output isn't actually being written in text-mode and it
was rather used as a workaround, disable text-mode for these tests.
|
|
|
|
|
|
|
|
|
|
According to section 2.2 of RFC959 the End-of-Line is defined as:
The end-of-line sequence defines the separation of printing
lines. The sequence is Carriage Return, followed by Line Feed.
Verified by sniffing traffic between a Windows FTP client (FileZilla)
and Unix-hosted FTP server (ProFTPD).
|
|
It makes more sense to convert the expected output to [CR][LF] on
Windows than to force the actual, probably correct, output to [LF].
This way it is actually possible to see if curl outputs the correct
line-ending excepted by a text-aware test case.
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Since the previous complex select function with initial support for
non-socket file descriptors, did not actually work correctly for
Console handles, this change simplifies the whole procedure by using
an internal waiting thread for the stdin console handle.
The previous implementation made it continuously trigger for the stdin
handle if it was being redirected to a parent process instead of
an actual Console input window.
This approach supports actual Console input handles as well as
anonymous Pipe handles which are used during input redirection.
It depends on the fact that ReadFile supports trying to read zero bytes
which makes it wait for the handle to become ready for reading.
|
|
Removed Unix-specific functionality in order to support Windows:
- select.epoll replaced with select.select
- SocketServer.ForkingMixIn replaced with SocketServer.ForkingMixIn
- socket.MSG_DONTWAIT replaced with socket.setblocking(False)
Even though epoll has a better performance and improved socket handling
than select, this change should not affect the actual test case.
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
This covers changes from commit afd288b2.
|
|
As was introduced in 8f6b4be8af04
|
|
|
|
Also, make the ftp server return a canned response that doesn't
cause XML verification problems. Although the test file format
isn't technically XML, it's still handy to be able to use XML
tools to verify and manipulate them.
|
|
Since /dev/stdout is not always emulated on Windows,
just skip the output option on Windows.
MinGW/msys support /dev/stdout only from a new login shell.
|
|
tstunnel on Windows does not support the pid option and is unable
to write to an output log that is already being used as a redirection
target for stdout. Therefore it does now output all log data to stdout
by default and secureserver.pl creates a fake pidfile on Windows.
|
|
The built-in memory debug system doesn't work with multi-threaded use so
instead of causing annoying false positives, disable the memory tracking
if the threaded resolver is used.
|
|
|
|
The Windows console version of stunnel is called "tstunnel", while
running "stunnel" on Windows spawns a new console window which
cannot be handled by the testsuite.
|
|
|
|
Previously LIST always returned a fixed hardcoded list that the ftp
server code knew about, mostly since the server didn't get any test case
number in the LIST scenario. Starting now, doing a CWD to a directory
named test-[number] will make the test server remember that number and
consider it a test case so that a subsequent LIST command will send the
<data> section of that test case back.
It allows LIST tests to be made more similar to how all other tests
work.
Test 100 was updated to provide its own directory listing.
|
|
|
|
This is desired to support stunnel installations on Windows.
|